Kontakt
PC Therm02-784 Warszawa, Poland
Ul. Aleksandra Janowskiego 6
contact us + 48 22 494 30 12 More contact data
Temperature Controllers - Standard Line
4 Channel Temperature Controller AI-7048
- 4 PID controllers in 1 housing!
- DIN rail
- 4 independent SSR outputs
Net price: €
Product description
AI-7048 is capable of measuring and controlling four channels of temperature, and every channel can define its own input specification.
AI-7048 can either work independently or cooperate with computer or PLC (Programmable Logic Controller).
It features:
- Providing up to four channels of configurable inputs, and supporting multiple thermocouple inputs with auto reference junction compensation and linear voltage inputs with user defined scale. Every channel has its own digital filtering and can adjust its filtering degree.
- High performance hardware design, which greatly decreased temperature drift and the
interference among the four channels. Therefore, this multi-channel instrument obtains the
same measurement accuracy and anti-interference ability as that of single channel instrument. - Every channel has independent high/low alarms, and the alarms can be allocated to different alarm outputs or to the same alarm output (Just available for Dimension E5).
- Friendly and customized operating interface leads to easy learning and simple manipulation. Up to 12 parameters can be promoted to immediate operator access in Field Parameter Table.
- Advanced communication functions, compatible with the communication protocol of other AI series instruments. One AI-7048 communicates with the host computer the same as four independent controllers.
- Universal power supply of 100-240VAC or 24VDC.
- New generation D5/E5 rail mounted dimension. The width of D5 is only 22.5mm. The instrument can be easily configured by connecting to handset display.
- ISO9001 and CE certified and satisfied with EMC standard, achieving world class level of quality, anti-interference ability and safety. The power and all I/O terminals passed 4KV/5KHz EFT test, and
the instrument can work stably under interference.
Controller is available in 2 dimensions:

E5 dimension D5 dimension
with E8 Operating Panel (sold separately)
Specifications
| Input type: | Thermocouple: K, S, R, E, J, T, B, N, WRe5-WRe26 Linear voltage: 0~20mV, 0~60mV, 0~100mV, 0~1V, etc. |
| Instrument input range: | K(0~1300°C), S(0~1700°C), R(0~1700°C), E(0~1000°C), J(0~1200°C), T(-200~+350°C), B(0~1800°C), N(0~1300°C), WRe5-WRe26(0~+2300°C) Linear Input: -9990~+30000 units defined by user |
| Measurement accuracy: | ± 0,2%FS ±0,1°C Note 1: For thermocouple input with internal compensation, cold junction compensation error up to 1℃ should be considered. For Cu resistor, freezing point or thermostat bath compensation, the error is small enough to be ignored. Note 2: B thermocouple can obtain the above measurement accuracy only at the range of 600~1800°C. It can measure temperature at 60~600°C with less accuracy. |
| Temperature shift: | ≤0,01%FS /°C (typical value is 60ppm/°C) |
| Isolation withstanding voltage: | between power, relay contact or signal terminal ≥2300VDC; between SSR voltage output and thermocouple input ≥600VDC |
| Control mode: | On/Off control mode AI artificial intelligence control, including fuzzy logic PID control and advanced control algorithm with the function of parameter auto tuning. |
| Outputs: | SSR, 12VDC/20mA for every channel |
| Alarm function: | High Alarm / Low Alarm |
| Power supply: | 100~240VAC, -15%, +10% / 50-60Hz; 120~240VDC; or 5VA. |
| Communication: | RS485 |
| Ambient temperature: | -10...+60°C |
| Relative humidity: | 0...90% |
| Certification: | ISO9001, CE |